Phone Call Icon

Call Us

+62 8882886888

My Account Icon

New Agilent HP 86142B 600 nm to 1700 nm Optical Spectrum Analyzer

$8.819

The Agilent 86142B Optical Spectrum Analyzer (OSA) is best suited for WDM component and system test applications where power and wavelength accuracy, dynamic range and low polarization dependency are key. The high performance capability of the Agilent 86142B OSA combined with the advanced feature set and on board measurement applications enables you to make highly accurate…

5 in stock

SKU: XRF0715
Category:

Description

The Agilent 86142B Optical Spectrum Analyzer (OSA) is best suited for WDM component and system test applications where power and wavelength accuracy, dynamic range and low polarization dependency are key. The high performance capability of the Agilent 86142B OSA combined with the advanced feature set and on board measurement applications enables you to make highly accurate measurements quickly and easily. These advanced features have been tailored towards increasing your product yields, maximizing manufacturing capacity and minimizing costs. The on-board measurement applications have been designed for ease of use requiring minimal training while retaining flexibility to customize measurements for individual needs.

Features :

  • Wavelength: 600 nm to 1700 nm
  • Reproducibility: ±0.002 nm (With applied input fiber 9/125 µm; = 1min)
  • Span Range: 0.2 nm to full range and zero span
  • Accuracy
    • After calibration with inteal source and with enhanced wavelength calibration for specified range:
      • 1480-1570 nm: Typ ±0.01 nm (At room temp; with applied input fiber 9/125 µm)
      • 1570-1620 nm: Typ ±0.025 nm (At room temp; with applied input fiber 9/125 µm)
    • After calibration with exteal reference source(s) ±10 nm of calibration reference point(s):
      • Typ ±0.01 nm (At room temp, with applied input fiber 9/125 µm)
    • After user calibration over full wavelength range (600-1700 nm):
      • ±0.2 nm (T(20-30°C), with applied input fiber 9/125 µm))
    • Absolute Accuracy:
      • ±0.5 nm (Factory cal. 2 yr. cycle; T(20-30°C); with applied input fiber 9/125 µm)
  • Tuning Repeatability: ±0.002 nm (With applied input fiber 9/125 µm; = 1min)
  • Resolution Bandwidth (RBW)
    • FWHM (3 dB Bandwidth): 0.06, 0.1, 0.2, 0.5, 1, 2, 5, 10 nm
  • Noise Marker Bandwidth Accuracy using noise markers 1525-1610 nm
  • Amplitude:
    • Sensitivity:
      • 600-750 nm: -60dBm (T(0-30°C), 2nd order)
      • 750-900 nm: -75dBm (T(0-30°C), 2nd order)
      • 900-1250 nm: -75 dBm (T(0-30°C)
      • 1250-1610 nm: -90 dBm (T(0-30°C)
      • 1610-1700 nm: -80 dBm (T(20-30°C)
  • Maximum Measurement Power:
    • 1525-1700 nm: Typ +15 dBm per channel, +30 dBm total 
    • 600-1000 nm: Typ +15 dBm per channel, +30 dBm total 
    • 1000-1525 nm: Typ +12 dBm per channel, +30 dBm total
  • Maximum Safe Power:
    • Total Safe Power: +30 dBm
    • Total power within any 10 nm portion of the spectrum: +23 dBm
  • Absolute Accuracy:
    • at –20dBm, 1310 nm/1550 nm: ± 0.5 dB (For resolution = 0.1 nm, with applied input fiber 9/125 µm)
  • Scale Fidelity:
    • Autorange off: ± 0.05 dB: T(20-30°C), with applied input fiber 9/125 µm
    • Autorange on: ± 0.07 dB: T(20-30°C), with applied input fiber 9/125 µm
  • Display Scale (log scale): 0.01-20 dB/DIV, -120 to +90 dBm
  • Amplitude Stability
    • (1310 nm, 1550 nm), 1 minute: ±0.01 dB (For signals within 8 dB of top of screen, with applied input fiber 9/125 µm)
    • 15 minutes: ±0.02 dB (Typ., with applied input fiber 9/125 µm)
  • Flatness:
    • 1525-1610 nm:  ±0.2 dB
    • 1250-1610 nm: ±0.7 dB
  • Polarization Dependence:
    • 1310 nm: ±0.25 dB 
    • 1530 nm, 1565 nm: ±0.2 dB 
    • 1600 nm:  ±0.25 dB
    • 1250-1650 nm: ±0.3 dB
  • Dynamic Range (In 0.1 nm Resolution Bandwidth):
    • 1250-1610 nm (chop mode on) ±0.5 nm, ± 1nm, ±5 nm: Typ -70 dB
    • 1550 nm
      • at ±0.8 nm (±100 GHz at 1550 nm): -60 dB
      • at ±0.5 nm (±62.5 GHz at 1550 nm): -58 dB
      • at ±0.4 nm (±50 GHz at 1550 nm): -55 dB
      • at ±0.2 nm (±25 GHz at 1550 nm): Typ -40 dB
  • Monochormator Input
    • Input Retu Loss:
      • Straight Connector (9/125 µm): > 35 dB
  • Sweep:
    • Max. Sweep Rate: Typ 40 nm/56.3 ms
    • Max. Sampling Rate in Zero Span: Typ 50 µs/trace point
    • Sweep Cycle Time:
      • 50 nm span, auto zero off: Typ < 180 ms
      • 50 nm span, auto zero on: Typ < 340 ms
      • 100 nm span: Typ < 400 ms
      • 500 nm span: Typ < 650 ms
  • ADC Trigger Accuracy:
    • Jitter (distributed uniformly): Typ < ± 0.5 µs
    • Trigger delay range: Typ 2 µs-6.5 ms
  • Pulse Mode Accuracy:
    • Tu On (=2 µs after rising edge): Typ <±0.2 dB
    • Tu Off (=10 µs after falling edge): <±0.2 dB (30 dB extinction)
  • Computer Interfacing
    • Remote Control: Web enabled controls
      • Compatibility: IEEE-488.1, IEEE-488-2 (100%)
      • Interfaces: LAN, GPIB, Parallel Printer Port, Exteal VGA Monitor, Keyboard and Mouse (PS/2)
    • Floppy Disk
    • Instrument Drivers: Universal Instrument Drivers (PNP), Compatible with VEE, Labview, Visual Basic and C++

Configuration Notes / Options:

 

  • 006 – Inteal wavelength calibrator